相信很多人都看了很多关于路由器配置方面的知识,在路由配置中也会出现很多问题,笔者某次配置了一个AM模块。出现了一个奇怪的问题。路由器配置好后,拨入时没有Modem拨号声。只有电话的声。并且音指示灯也不亮。当笔者拔下模块上的电话线时。指示灯亮了。
路由器配置
620#shrun Buildingconfiguration... Currentconfiguration:866bytes ! version12.2 servicetimestampsdebuguptime servicetimestampsJoguptime noservicepassword-encryption ! hostname2620 enablesecret5$1$pUrf$9xGOg.zyxKawi9NljLHHr1 usernameuserpassword0Cisco ipsubnet-zero ! ! noipDOmain-lookup ! ! ! ! interfaceFastEthernet0/0 ipaddress136.0.0.254255.255.0.0 duplexauto speedauto ! interfaceGroup-Async1 ipunnumberedFastEthernet0/0 encapsulationppp asyncdefaultrouting asyncmodeinteractive peerdefaultipaddresspoollab pppauthenticationchap group-range3348 ! ! ipclassless noiphttpserver ippimbidir-enable ! ! linecon0 passwordcisco line3348 loginlocal modemInOut autocommandppp transportinputall autoselectppp stopbits1 flowcontrolhardware lineaux0 linevty04 passwordCisco login ! noschedulerallocate end
诊断过程
笔者仔细检查路由器配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系。没自动应答:多半是接地问题。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了。
排除心得
路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好?,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰。接路由器电源的时候如果有地线,一般不需要我们再接地了。
转载请注明:IT运维空间 » 运维技术 » 讲述路由器配置错误导致的无法拨号问题